The HTP-003 series of high temperature electric transmitter two-wire system circulation output leads nonpolar; three-wire voltage and current output type AC and DC.
Generally used for hydraulic control, petroleum energy, transportation, mining industry, metallurgy equipment, marine engineering, automatic detection system, energy and water treatment equipment and other industrial equipment and facilities.
Ordering:
Input signal | Connection type | Pressure portthreads | Addition |
A= 4 ~ 20mA B=0 ~ 20mA D=0~ 10V | H=HIRSCHMANN plug C=Cableline outlet | Ga=G1/4 thread Gb=G1/2 thread Na=1/2 NPT thread Nb=1/4 NPT thread Ma=M20X1.5 face seal thread Mb=M20X1.5 waterline seal thread U=7/16 -20UNF threads | La=Gauge with LED Lb=Gauge with LED and 2 control points Va=10-30VDC G=Gauge pressure. A=Absolute pressure S=Sealed gauge pressure M=Intrinsically safeexplosion-proof Exia IICT6 Ua=0.25%F.S accuracy Ub=0.5%F.S accuracy |
Specification:
Item | Description | |
Pressure range | Within 0.1MPa ~ 70MPa | |
Overload pressure | 2 Times the ratedpressure | |
Damage pressure | 4 Times the ratedpressure | |
Accuracy | ±0.1%F.S/ ±0.25%F.S / ±0.5%F.S | |
Stability | Typical value: 0.25%F.S/Max. value: 0.4%F.S | |
Operationtemperature | -50℃ ~ 150℃ | |
Compensationtemperature | -20℃~120℃ | |
Compatible media | All corrosive mediacompatible with 1Cr18Ni9Ti | |
Electricalproperties | 2- lines: 4~20mA 3- lines: 0~20mA /0~10VDC / 12~30VDC 4- lines: 0~20 mA /0~10VDC / 12~30VDC | |
Load resistance | 2- lines: (U-10) / 0.02(Ω) 3- lines and 4-lines : Elec. Current: (U-12) / 0.02(Ω) Voltage:>100K Ω | |
Insulation | >100M Ω at 50V | |
Electricalconnection | Thewater outlet ( five waterproof sealed), shell protection IP68 | |
Shell protection | IP67 | |
Pressure portthreads | M20×1.5,G1/2,G1/4,NPT1/2,NPT1/4,NPT1/2 | |
Form of pressure | G= Gauge pressure/ A= Absolute pressure / S= Sealed gaugepressure | |
Electromagneticcompatibility | Electromagnetic radiation: EN50081-1/-2; Electromagnetic sensitivity: EN50082-2 |
Dimensions:
Connector type | ||||
Plug | 2 Wires | Cable | 3 Wires | Cable |
1 | Power | Red wire | Power | Red wire |
2 | Output | Blue/Green wire | Power ground | Black wire |
3 | Output | Blue/Green wire | ||
4(E) | Shielded | Yellow wire | Shielded | Yellow wire |
Pressure port connection threads | |||||
1 | M20X1.5 | 3 | NPT 3/8 | 5 | G 1/4 |
2 | NPT 1/4 | 4 | NPT 1/2 | 6 | G 1/2 |
Form of signal output | |
2- LINES | 4-20mA |
3- LINES | 4-20 mA; 0-10 mA; 0-20 mA |
0- 5VDC; 0.5 – 4.5VDC; 1 - 5VDC; 0 - 10VDC | |
4-LINES | 4-20 mA; 0-10 mA; 0-20 mA |
0- 5VDC; 0.5 – 4.5VDC; 1 - 5VDC; 0 - 10VDC |