The use of media for Cone Penetration degree of 250 to 350 ( 25 ° C , 150g) the 1/10mm grease ( NLGI0 # -2 #) .
How to use the 220V-50Hz Directional Valve Control Electric Lubrication Grease Pump:
1. 220V-50Hz Directional Valve Control Electric Lubrication Grease Pump should be installed in a suitable ambient temperature, low dust, easy adjustment, inspection, maintenance and removable and washable grease filling convenient place.
2. The series of DXZ
grease pump, as far as possible, disposed in the center position of the system and shorten the length of the system piping, to maintain a minimum pressure drop, so that the pump can generate a pressure sufficient to overcome the back pressure of the lubricating points.
3. Before operation, it must first be fillet with 50 # machine oil in the gear box to the standard liquid level in the lubrication system.
4. It must to complement grease in the reservoir with DJB-200 electric pumps from grease storage refueling filler, it is not allowable to start the pump with our grease in the reservoir.
5. The solenoid valve connection interface Rc3 / 8 gauge ports are available, such as when not needed Rc3 / 8 plugs blocked.
6. The solenoid valve on the regulator, in the range of 0 ~ 10MPa be adjusted in use does not allow more than the pump nominal pressure (10MPa).
7. The
lubrication system in the early months must remove the two end of the solenoid valve electromagnet check joints from the push rod seal leakage and leakage, if any, should replace the seals in a timely manner so as not to burn the coils note that regular checks.
8. The series of DXZ pump is for indoor installation and use of outdoor or harsh environment applications, protective measures must be taken.